Spectrometers / "ElvaX Light" Spectrometer |
|
|
 |
|
"ElvaX Light" Spectrometer | ElvaX Light is a desktop energy-dispersive X-ray fluorescence (EDXRF) analyzer with extended element range from Na (Z=11) to U (Z=92). The Helium purge system and the automatic primary filter changer are used to allow effective registration of the light elements spectra. ElvaX Light is used for quantitative and qualitative analysis of the elemental composition of metal alloys, liquids, food and biological samples, powder assays, as well as samples deposited on surfaces or filters, in a wide range of element concentrations. The accuracy of determining concentrations is better than 0.3% for metal alloys. Analyzer's detecting limit is better than 1 ppm for most elements in light matrix.
| The spectrometer is registered in the State registry of measurement instruments accepted for usage in Ukraine under the number Ó1411‑01. Certificate of the measurement instrument type is UA‑MI/1‑971‑2001.Fields of application- RoHS & WEEE
- Jewelry
- Metallurgy
- Medical diagnosis
- Ecological monitoring
- Customs and criminalistic expertise
- Archaeological studies
- Chemical industry
- Oil-refining industry
- Geology and mineralogy
- Food industry
- Scientific research
| Element detection range | from Na (Z=11) to U (Z=92) | | Data acquisition time | 10 – 1200 s | | Power supply | 90 - 240 V, 50/60 Hz | | Power consumption | 40 W | | Dimensions | 430 mm x 340 mm x 200 mm | | Weight | 18 kg |
Technical characteristicsX-ray source | X-ray tube | Ti or Rh anode 140 µm Be window air-cooling | | X-ray generator | voltage: 4–50 kV, adjustable in 100 V steps current: 0–100 µA, adjustable in 0.2 µA steps maximal power: 5 W | | Stability | 0.1% per 8 hours |
X-ray detector | Detector type | solid state Si-pin-diode with thermo-electrical cooling | | Active area | 6 mm2 | | Energy resolution | 165 eV at 5.9 keV (Fe55 isotope) | | Be window thickness | 8 µm |
Spectrometric processor | Pulse processor | digital pulse processor pile-up rejection pulse shape selector automatic adjustment to count rate | | ADC | 4096 channels | | Buffer RAM | 4096 32-bit channels | | Timers | real and "live" time |
Software | Supported operating systems | Windows 98/NT/2K/XP | | Quantitative analysis algorithms | fundamental parameters quadratic stepwise multiple regression manual spectra comparison |
Options | Built-in CCD Camera | VGA 640x480 | | Autosampler | 8 positions, 32 mm diameter |
Click here to view the screenshot of the ElvaX software
|
|
|
 |
|
|
|